Shanghai Autra Precision Surface Treatment Co., Ltd.

AUTRA / PTFE COMPOSITE PLATING

Electroless Nickel-PTFENi-P / PTFE composite coating

Smoother, less sticky precision surfaces. PTFE particles are co-deposited in an electroless nickel coating for sliding fits and mold release needs.

30–35 vol% PTFE · friction coefficient μ0.05–0.08

Data reference range corresponding to a PTFE volume fraction of 30–35 vol%, not a guarantee for any workpiece. Friction coefficient is affected by counterpart, load, speed and lubrication state; verify by the corresponding content group and actual conditions—conditions from different groups cannot be applied to one another.

PTFE surface effect animationConcept demo · not friction coefficient test footage

Low-friction surfaces for precision motion and mold release

A Ni-P matrix and PTFE particles form a composite coating. When selecting, check friction, wear and adhesion together with the part's shape and surface requirements.

01 / SLIDING

Sliding fits

For piston rods, guide shafts, pneumatic valves and similar parts; evaluate counterpart, lubrication state and allowable wear.

02 / RELEASE

Mold release & non-stick

For resin molds and forming tools; confirm the effect with contact material, temperature and cleaning method.

03 / ENGINEERING

Select by workpiece

Provide substrate, dimensions, working surfaces and pretreatment restrictions; an engineer will evaluate the coating and verification method.

See the friction coefficient ranges below by PTFE volume fraction. Friction coefficient is dimensionless; actual behavior is also affected by counterpart material, load, speed and lubrication state.

Test charts & test conditions

See comparisons of oil lubrication, contact angle and surface condition for PTFE composite coatings, plus historical references for content and heat treatment. Test conditions for each group are listed under the charts.

SRV oil lubrication: friction coefficient & wear depth

Friction coefficient under oil lubrication
Friction coefficient under oil lubrication Enlarge ↗
Wear depth under oil lubrication
Wear depth under oil lubrication Enlarge ↗

Test method & conditions

Test equipment
SRV
Test equipment
SRV
Load / frequency
50 N / 50 Hz
Time / amplitude
30 min / 1 mm
Coated substrate / counterpart
A5056 / SUJ2
Lubricant
10W-30 base oil, 200 μL
Temperature
Room temperature 30 ℃

Japanese factory test values, not guaranteed values. Bar lengths are read from the original charts and values are approximate; they apply only to the listed test conditions.

Source

Original test data page ↗

PTFE composite coating vs. PTFE coating: 2 μL contact angle comparison

Contact angles of PTFE composite coating and PTFE coating
Contact angles of PTFE composite coating and PTFE coating Enlarge ↗

Test method & conditions

Test instrument
Kyowa Interface Science Dmo-502 (as labeled in source)
Droplet
Pure water 2 μL
Substrate
50 × 50 mm SPCC plate; untreated iron plate as control
PTFE-S composite coating
approx. 10 μm; not heat-treated
PTFE fluororesin coating
approx. 30 μm; black; baked at 400 ℃

Japanese factory test values, not guaranteed values. PTFE-S is the source's S-series composite coating; this group and the existing 1 μL, 300 ℃, 10 s contact angle test are kept separately.

Source

Original test data page ↗

Surface roughness before and after plating

Ni-P surface roughness before and after plating
Ni-P surface roughness before and after plating Enlarge ↗
PTFE-S composite coating surface roughness before and after plating
PTFE-S composite coating surface roughness before and after plating Enlarge ↗

Test method & conditions

Substrate
50 × 50 mm SPCC plate
Coating / thickness
General electroless nickel Ni-P / PTFE-S composite coating; both 10 μm

Japanese factory test values, not guaranteed values. Table values are transcribed exactly; missing units are kept as in the original table. PTFE-S refers to the source's S-series composite coating.

Source

Original test data page ↗

PTFE content & performance orientation

Relationship between PTFE content, lubricity and hardness
Relationship between PTFE content, lubricity and hardness Enlarge ↗

Test method & conditions

Nature of data
Qualitative relationship diagram, no numerical scale

The chart expresses the directional relationship between content and performance to explain selection thinking.

Source

Original test data page ↗

PTFE composite coating: hardness reference after 200 ℃ and 300 ℃ heat treatment

PTFE-BPTFE-APTFE-S
Post-plating heat treatment 200℃400~550Hv250~350Hv200~300Hv
Post-plating heat treatment 300℃750Hv or above400~600Hv300~400Hv

Test method & conditions

Specimen series
Source PTFE-B / A / S series
State
Post-plating heat treatment 200 ℃ / 300 ℃, listed separately

This table is a Japanese factory specimen reference, not guaranteed values, and cannot be used directly as acceptance criteria for the products on this page. The B series is recorded as ≥750 HV at 300 ℃; this value only indicates the lower limit in that data.

Source

Original test data page ↗

Detailed technical parameters & applicable conditions

On mobile, swipe left and right to see the full table.

ItemNotes
Self-lubricatingPTFE particles distributed on the surface and inside the coating help improve sliding behavior.
Non-stick & hydrophobicFor discussing mold release, droplet adhesion and cleaning needs; effects must be verified with actual contact substances and conditions.
Conductivity & heat transferThe metal matrix differs from pure PTFE coatings in electrical and thermal behavior; please provide specific contact resistance, static or thermal conductivity requirements.
Corrosion resistance & adhesionAffected by substrate, pretreatment, coating thickness and porosity; "uniform coverage" should not be understood to mean every workpiece is necessarily pinhole-free.
How to read this table

Look at the item first, then check the corresponding values and heat treatment conditions. Loads, times and standards for each group correspond to specific tests; formal specifications are confirmed per process and workpiece.

Part applications & selection focus

On mobile, swipe left and right to see the full table.

Application directionTypical parts or usesConditions to confirm
Sliding fitsPlungers, piston rods, guide shafts, valvesCounterpart, lubrication method and allowable wear
Mold release & cleaningResin molds, hoppers, forming toolsContact material, temperature, release force and cleaning method
Precision assembliesDifferential gear washers, semiconductor equipment partsClearance, particle requirements and surface condition
How to read this table

Uses are compiled from technical data and application directions and do not mean every workpiece is suitable. After identifying the key failure problem, agree on the coating and verification method.

Images & technical documents

The four SEM images below are arranged by the PTFE content groups above, extracted directly from the original images embedded in the technical data PDF, each keeping its own scale bar.

Related performance & test data

Limits of applicability

Public data is a reference for the product system and coating performance; please request the corresponding technical documents to confirm specific chemical processes, bath conditions, thickness and acceptance requirements.

Selection notes

Plating service customers only need to provide targets, substrate and quantity; an engineer will determine the coating. Chemical customers should also provide tank size, current process, operating temperature and production takt to confirm the specific process TDS.

Source: company technical data ↗; Japanese series data and micrographs: "PTFE composite coating technical data" · Updated: 2026-09-30

Application needs & evaluation cases

View candidate coatings, related Q&A and verification checklists in the context of specific part failure problems.