Shanghai Autra Precision Surface Treatment Co., Ltd.

Surface treatment · process selection

Special substrates · neutral Ni-P system

Room-temperature electroless nickel

Neutral low-temperature Ni-P system

This process is a neutral Ni-P system that can plate at relatively low temperatures, suitable for substrates such as glass, ceramics and pottery. The coating has low deformation and good adhesion, with single-solution make-up and single-batch use, easing process selection around substrate and temperature conditions.

Glass / ceramics / pottery

Applicable substrates listed in the instructions

pH 7.00±0.10

Neutral Ni-P system

30–90℃

Operating temperature range

Process scenario & substrate references

From the plating scene to glass and ceramic workpieces

The first image is a user-provided concept image of the process scene; the other two show related substrate forms. Actual adhesion and plating results must be verified on the specific workpiece and pretreatment.

Concept illustration of an electroless bath, racks and specimens; not an actual production site photo or real temperature record
Low-temperature plating scene illustrationUser-provided concept image; gauge readings in the image are visual elements only and do not represent this process's parameters.
Reference photo of alumina ceramic structural parts, not plated with this process
Alumina ceramic structural partsSubstrate illustration · Ezrado / Wikimedia Commons · CC BY-SA 4.0
Reference photo of glass substrate (microscope slides), not plated with this process
Glass substrate (microscope slides)Substrate illustration · Whispyhistory / Wikimedia Commons · CC BY-SA 4.0

The first image is a concept illustration; the other two are substrate references not plated with this process. None are site photos or test results.

1 / Process features

Selection around special substrates

Confirm suitable plating conditions with substrate, allowable temperature and target thickness.

01

Substrate compatibility

Glass & ceramic applications

Low coating deformation, good adhesion

Suitable for substrates such as glass, ceramics and pottery. When selecting, focus on substrate surface condition, pretreatment and adhesion on actual workpieces.

  • The instructions explicitly cover glass, ceramics and pottery.
  • Low coating deformation and good adhesion.

Ni-PNi-P alloy coating

02

Temperature selection

Supports low-temperature plating

Evaluate temperature and deposition rate together

Operating temperature covers 30–90℃. The instructions give the temperature–rate relationship for a fresh bath, which can be evaluated against workpiece temperature requirements and plating time.

  • At 30℃, the fresh-bath plating rate is 1.25 μm/h.
  • At 90℃, the fresh-bath plating rate is 30±2 μm/h.

30–90℃Different temperatures give different plating rates

03

Production method

Single-solution make-up

Single-batch use, easy to manage

Uses single-solution make-up and is a single-batch electroless nickel chemical. Arrange batches with plating area, thickness and bath consumption.

  • Bath made up with a single chemical component.
  • Single-batch use, easy to manage.

Neutral systempH 7.00±0.10

2 / Performance parameters

Use clear process conditions as reference

"Neutral" and "low-temperature" refer to pH and operating temperature respectively and should be evaluated together with the specific substrate.

On narrow screens, swipe left and right to see all parameters →

Room-temperature electroless nickel features & process conditions
ItemParameterConditions & notes
Coating systemNi-PNeutral Ni-P system
Applicable substratesGlass, ceramics, pottery, etc.Confirm adhesion with pretreatment and actual workpieces
Coating featuresLow deformation, good adhesionQualitative description from the instructions; adhesion and deformation are verified per workpiece
pHpH 7.00±0.10Operating conditions
Operating temperature30–90℃Plating rate varies with temperature
Deposition rate30±2 μm/hFresh bath, 90℃
Nickel sulfate concentration20±2 g/LNickel sulfate hexahydrate NiSO₄·6H₂O; not the metallic nickel concentration
UsageSingle-solution make-up, single-batch useOne-batch process described in the instructions
  1. The deposition rate at 90℃ cannot represent low-temperature plating speed; see the table below for data at different temperatures.
  2. The above is for process selection and does not replace the full operating instructions.

3 / Temperature & plating rate

Evaluate plating rate by workpiece temperature requirements

All data below are fresh-bath data. Low-temperature plating requires evaluating processing time against the target thickness.

On narrow screens, swipe left and right to see all parameters →

Room-temperature electroless nickel temperature vs. deposition rate · fresh bath
TemperatureDeposition rateData conditions
30℃1.25 μm/hFresh bath
35℃1.65 μm/hFresh bath
40℃2.15 μm/hFresh bath
50℃3.75 μm/hFresh bath
60℃6.90 μm/hFresh bath
70℃12.2 μm/hFresh bath
80℃19.0 μm/hFresh bath
90℃30.0 μm/hFresh bath; the operating conditions table separately lists 30±2 μm/h

The above data is the temperature–rate relationship from the instructions and does not represent a sustained guarantee at any bath age or workpiece condition.

4 / Application selection

Start with substrate and temperature conditions

Provide the substrate, target thickness and allowable temperature to help confirm a suitable evaluation plan.

01

Glass, ceramics & pottery

Focus on coating adhesion, substrate compatibility and temperature conditions.

Evaluation direction: neutral electroless nickel for glass & ceramics

Confirm pretreatment according to substrate and surface condition, then verify on actual workpieces.

02

Temperature-limited plating needs

Focus on allowable temperature, target thickness and processing time.

Evaluation direction: matching temperature and plating rate

First confirm the workpiece temperature limit, then evaluate plating conditions with fresh-bath data.

Selection summary

Start from substrate compatibility, then choose the plating temperature.

Room-temperature electroless nickel targets substrates such as glass, ceramics and pottery, meeting neutral, low-temperature plating and adhesion needs. Set the evaluation range by allowable temperature and confirm the process with target thickness and actual workpieces.

5 / FAQ

Distinguish pH from phosphorus content

Is "neutral electroless nickel" the same as "mid-P electroless nickel"?

"Neutral" refers to bath pH; room-temperature electroless nickel operates at pH 7.00±0.10. "Mid-P" describes the phosphorus content of the deposited coating. This process is selected for special substrates such as glass and ceramics, and bath pH cannot be used to infer the coating's phosphorus classification.

Can it reach 30 μm/h at low temperatures too?

30±2 μm/h corresponds to fresh bath at 90℃. The instructions list a fresh-bath rate of 1.25 μm/h at 30℃; plating time must be evaluated at the chosen temperature.

Is it suitable for all substrates?

The instructions list it as suitable for glass, ceramics, pottery and similar; metals that act as catalytic poisons such as bismuth, cadmium, antimony, tin, lead, solder and zinc are not suitable. Specific workpieces should be confirmed with substrate composition and pretreatment.

Compiled from the provided process instructions. Values are for selection reference; final results are subject to process confirmation and testing on the specific workpiece.

Back to top ↑

Confirm a room-temperature electroless nickel solution with an engineer

Please provide the substrate, target thickness, adhesion requirements and allowable temperature; for parts plating, also specify quantity and drawing requirements.