Shanghai Autra Precision Surface Treatment Co., Ltd.
← Coating performance & selection

Wear resistance

Read wear loss and hardness separately, and choose the coating by the actual friction mode.

The following are laboratory / historical comparison data and are not a guarantee for any workpiece; formal specifications are subject to engineer confirmation and the quotation.

PROCESSING · PERFORMANCE

Processing customers, start here

Improve resistance to indentation

A specific composite coating: HV550–600 as-plated; HV1000–1200 after heat treatment.

This record applies to a SiC composite coating with 300°C heat treatment; holding time, test load, etc. need confirmation, and it does not represent all processes. Hardness is not wear life; please state separately whether the substrate allows heat treatment.

Tell our engineers your requirements

Enter substrate, quantity and performance targets; if you don't know the specific metrics, you can describe the problem you face.

Detailed test data · expand test conditions, historical data and interpretation

Conclusions first

The wear test used a 15 μm coating; the hardness test used 30 μm—these are two separate experiments.

Complete wear and hardness curves are listed separately; confirm the test conditions first, then compare trends at the same heat-treatment temperature.

Hardness is not the only indicator of wear resistance; the counterpart, load and lubrication conditions must be considered too.

Test conditions

Wear test | Suga

Standard / equipment
Suga abrasion tester
Medium
Dry environment
Load
1.5 kg (load notation as in source)
Counterpart
#2000 waterproof abrasive paper
Thickness
15 μm
Heat treatment
Heat-treatment temperature on the curve's horizontal axis

Wear area 30 × 12 mm; 300 reciprocations. Heat-treatment temperature on the curve; comparisons are limited to this group's test conditions.

Hardness test | Vickers microhardness

Standard / equipment
Vickers microhardness tester
Load
25 g (load as labeled in source)
Counterpart
No sliding counterpart applicable
Thickness
30 μm
Heat treatment
Heat-treatment temperature on the curve's horizontal axis

Wear & hardness: read the two tests separately

Redrawn values are manual readings of marked points in the source charts and cannot replace original measurement data. "—" means no corresponding marked point; 0°C follows the original chart's starting-point notation and does not mean actual 0°C heat treatment. The ceramic composite coating is read as a separate specimen.

On mobile, swipe the chart left/right; tap a chart to open the large image.

Wear loss · coatings compared row by row
Wear loss · coatings compared row by row

On mobile, swipe the chart left/right; tap a chart to open the large image.

Vickers microhardness · coatings compared row by row
Vickers microhardness · coatings compared row by row
View point-by-point readings of the redrawn wear and hardness charts

The following are approximate manual image readings; "—" means no corresponding marked point in the original chart, not zero. Actual marked points of each curve are kept without interpolation.

Wear loss / mg · coating 15 μm

Coating / heat-treatment temperature °C80150200250300350400
Ni-P-B≈ 1.6≈ 1.0≈ 0.8≈ 1.0≈ 1.2≈ 1.0≈ 0.8
PTFE A≈ 9.0≈ 8.8≈ 8.6≈ 8.0≈ 6.5≈ 5.6—
PTFE B≈ 6.5≈ 6.7≈ 6.6≈ 6.5≈ 6.1≈ 4.9—
Ceramic composite coating≈ 3.3≈ 3.0≈ 2.7≈ 2.0≈ 1.8≈ 1.2≈ 1.1
Ni-P≈ 5.2≈ 5.2≈ 5.4≈ 5.0≈ 4.3≈ 4.4≈ 4.5

Vickers hardness / HV · coating 30 μm

Coating / heat-treatment temperature °C0150200250300350400
Ni-P-B≈ 740—≈ 800—≈ 900≈ 930≈ 960
PTFE A≈ 300≈ 305≈ 310≈ 320≈ 520≈ 550—
PTFE B≈ 500≈ 500—≈ 520≈ 810≈ 830—
Ceramic composite coating≈ 630≈ 635≈ 645—≈ 960≈ 1010≈ 1030
Ni-P≈ 520≈ 525≈ 535≈ 580≈ 850≈ 865≈ 935

Wear specimens 15 μm, hardness specimens 30 μm; point heights are only for comparison within each chart, and the two charts cannot be cross-converted into service life. The original charts are kept below for checking.

Data & interpretation

What each test measures

The table scrolls horizontally; the first column keeps the comparison items.

TestResult metricCoating thickness
Suga abrasionMass loss, mg; smaller means less wear in this test15 μm
Vickers microhardnessVickers hardness, HV; not wear life30 μm
How to read this table

Both tests use heat-treatment temperature as the horizontal axis, but coating thickness and test method differ. The curves show comparative trends; image readings are not treated as original measurements or contract specifications.

Test charts & test conditions

View charts, methods and conditions test by test. Vector charts can be clicked to enlarge; each data group applies only to the corresponding specimens and test conditions.

Oil-fed reciprocating wear: coating and counterpart wear

Coating wear amount
Coating wear amount Enlarge ↗
Counterpart wear amount
Counterpart wear amount Enlarge ↗
Oil-fed reciprocating wear setup
Oil-fed reciprocating wear setup Enlarge ↗

Test method & conditions

Running-in stage
1 kgf;100 cpm;5 min
Main test
3 kgf;600 cpm;60 min
Oil feed in both stages
Both 1.8 cc/h
Counterpart treatment
Nitriding / chrome plating

Japanese factory test values, not guaranteed values. Bar lengths are read from the original charts. The two result charts show coating wear and counterpart wear respectively; this group’s conditions are used on their own.

Source

Original test data page ↗

Original page of related data ↗

Abrasive wear test with hard chrome comparison

Abrasive wear comparison of electroless nickel coatings and hard chrome
Abrasive wear comparison of electroless nickel coatings and hard chrome Enlarge ↗

Test method & conditions

Standard cited by source
JIS H 8503 (as cited by source)
Test equipment
Suga NUS-ISO3 (as labeled in source chart)
Load / reciprocations
2.5 kgf / 300 cycles
Abrasive
#2000 abrasive paper
Hard chrome specimen
Not ground after plating; not heat-treated
Other coating conditions
Not heat-treated / 200 ℃ / 300 ℃

Japanese factory test values, not guaranteed values. Bar lengths are read from the original chart. This 2.5 kgf test and the existing 1.5 kg temperature–wear test on this page are shown separately, each with its original conditions.

Source

Original test data page ↗

General electroless nickel: heat-treatment temperature vs. hardness

Ni-P heat-treatment temperature–hardness curve
Ni-P heat-treatment temperature–hardness curve Enlarge ↗

Test method & conditions

Specimen
General electroless nickel Ni-P
Heat-treatment temperature
Horizontal axis 0–700 ℃, see chart

Japanese factory test values, not guaranteed values. The curve is read from the original chart to illustrate the heat-treatment trend; it cannot be used directly as an acceptance curve for current products.

Source

Original test data page ↗

Original page of related data ↗

Abrasive paper wear method diagram

Abrasive paper wear test setup diagram
Abrasive paper wear test setup diagram Enlarge ↗

Test method & conditions

Nature of method
Setup structure diagram
Existing temperature–wear curve
Suga; #2000 waterproof abrasive paper; wear area 30 × 12 mm; 1.5 kg; 300 cycles; coating thickness 15 μm
Vickers microhardness curve
Test load 25 g; coating thickness 30 μm

The existing temperature–wear and Vickers microhardness curves are not repeated; the diagram helps explain the measuring method.

Source

Original test data page ↗

Original page of related data ↗

Selection advice & data boundaries

Note: higher hardness does not necessarily mean better wear resistance. Around 300°C, the blue ceramic composite coating is harder than the cyan Ni-P-B, yet its wear loss is also larger; comparisons are limited to each historical test's conditions. Ni-P and some composite coatings show different trends, so it cannot be generalized that higher temperature always means better wear resistance.

The ceramic composite coating in the chart is read as a separate specimen and is not directly equivalent to this site's Ni-P + SiC product. For actual selection, candidates such as SiC composite electroless nickel and electroless Ni-P-B can be evaluated, with comparison tests on the actual counterpart.

Please provide the counterpart material, contact mode, load, speed, lubricating medium and allowable wear; whether the substrate can withstand heat treatment must be confirmed separately.